SUPPORT
Measurement data is stored in the BATCAM’s internal memory in .jpg or .avi format. A USB storage device with a “FAT 32” format is required to export the data. You can connect the storage to a USB port located on the left side of the product to enable the data export function.
BATCAM 2.0 can detect not only gas leak but also the location of noise caused by electric or mechanical faults. By adjusting the measurement frequency band and the sound pressure filter, the BATCAM 2.0 can visually pinpoint noises coming from specific locations up to 50 m(150 ft) away.
For equipment with multiple microphone sensors, the higher the number of sensors, the higher the performance of the equipment. In the case of BATCAM 2.0, 112 microphones are optimized in a unique sensor array to produce visually measurable images in audible and ultrasonic frequencies.