See What You’ve been Missing!

From the Sound of the Ear, To the Minute Air · Gas Leak, and the Electric Arc!


BATCAM 2 is the world’s lightest and smallest ultrasonic / sound camera. It can be used for various objectives, because it can measure not only signal in audible range but also in ultrasonic range. It has 112 microphones for high measurement sensitivity and can detect ultrasonic signal at 48kHz. BATCAM 2 can clearly measure not only car BSR(Buzz, Squeak, Rattle), but also the minute air · gas leak, and the electric arc. It will continually increase productivity and comfort.

mobile background


See What You’ve been Missing! 

From the Sound of the Ear, To the Minute Air · Gas Leak, 

and the Electric Arc!


BATCAM 2 is the lightest and smallest ultrasonic and acoustic sound camera. This rugged, versatile tool can help you quickly and easily identify a variety of undesirable industrial conditions. With pinpoint accuracy the BATCAM 2 allows you to instantly see audible and ultrasonic noises that are hard to detect. With 112 MEMS based precision microphones, the BATCAM 2 will help you clearly see what you've been missing.

Measurement of Car BSR Noise and Identification of Causes
Measurement of Car BSR Noise and Identification of Causes
Visualization of Air · Gas Leak, and the Electric Arc Location
Visualization of Air · Gas Leak, and the Electric Arc Location
Noise Diagnosis and Evaluation in Industrial Sites
Noise Diagnosis and Evaluation in Industrial Sites

Hardware

  • 112 Ch High Performance MEMS Microphone
  • Measure and Analyze up to 48 kHz
  • Audio and HDMI Output
  • 5-inch Touch Screen
  • Available for 4 Hours
  • Include Distance Sensor
  • Two Lights Adjustable

Software

  • Visualize and Display Sound in Real Time
  • Single/Multiple/Full view source Measurement mode selectable
  • Band Pass Filtering
  • Save Images
  • Accuracy Improvement over Distance
  • Digital Zoom
  • Real-time PRPD Analysis and Partial Discharge Measurement
  • Show Air/Gas Estimated Leak Index

Principle of Ultrasound Measurement

Gas leaks result in higher ultrasonic components than audible frequency. Ultrasonic components also occur when electric discharge occurs. Therefore, it is possible to measure the presence and location of gas leaks or electric discharge by measuring the ultrasonic components in a noisy environment. BATCAM 2 can detect a leak rate of 51 cc/min at a distance of 0.5 m under a pressure condition of 0.2 bar. If the leak rate is higher, the detection distance can be even greater. If the leakage flow is greater, it can be measured from a longer distance.

Specifications


Specifications
Sensor(Microphone)112Ch Digital MEMS
Effective Frequency Range
2 k ~ 48 kHz
Acoustic Measurement

Detection threshol

2 kHz : 2.80 dB SPL

20 kHz : 12.72 dB SPL

40 kHz : 1.10 dB SPL

Minimum leak rate  0.5 m, 0.2bar, 51 cc/min

Minimum leak rate 
0.5 m, 0.2bar, 51 cc/min
Test Distance

0.5 ~ 100 m

Camera pixel / FOV
8MP / Horizontal 63º, Vertical 40°
Image Resolution1024 x 608
Frame Rate 25 FPS
Digital Zoom 
Auxiliary lights
 x2 ZOOM / LED x 2
Display Resolution5" Color LCD (800 x 480)
Brightness250 nit
Touch ScreenCapacitive Touchscreen




Data Format
JPG

Storage 

53 GB (Save 370,000 Pictures)
Data transfer
External USB
Hardware Ports
USB-A, Audio and HDMI outputs

Operating time (charging time) 

Up to 5 hours (4 hours)

Built-in Battery

Rechargeable Battery - Li-ion (48.24 Wh)

Samsung SDI INR18650-35E

Operating temperature
-20 ~ 50  ℃
Product Size / Weight
237 x 146 x 56 (mm) / 1.2 kg
Supported Language

Chinese (Traditional, Simplified),Croatian,Dutch, 

English, French, German, Japanese,Korean, 

Portuguese, Russian, Spanish,Thai, Turkis

Warranty
extension program

Basic Warranty 1 Year 

Additional 2 years +1,800,000 KRW 


Product Comparison Table



BATCAM 2.0 ResultCompany A
Number of MicrophonesDigital MEMS 112ExcellentDigital MEMS 64
Frequency Range
2 kHz ~ 48 kHz
equivalent2 kHz ~ 52 kHz
Microphone Sensitivity
1.83 cc/sec (110cc/min) at 10 m
10m to 110m/minute leak
0.85 cc/sec(51cc?min) at 0.5 m
0.5m to 51ml/minute leak
Excellent2.5 cc/sec (150cc/ml) at 10m
10m to 150ml/minute leak


Sensor Minimum
Detection Range
0.3m
Excellent0.5m
Minimum measurable level
(dB,Ref,20μpa, dB SPL)
(Self-Performance Assessment Results)
10 kHz, -26dB
20 kHz, -45dB
30 kHz, -32dB
40 kHz, -22dB
Excellent
10 kHz, -25dB
20 kHz, -30dB
30 kHz, -16dB
40 kHz, -10dB
Frame Rate25 FPSequivalent
25 FPS
Display Type5” Color LCDequivalent
7-inch LCD
Acoustic Image / FOVAcoustic Beampower Map / 60°equivalent
Sound Map / 63°±5° 
Battery LifeUp to 4.0 Hours (Additional 8 Hour External Battery)Excellent
6.0 Hours
Operating Temperature
-20℃ ~ 50℃Excellent
-10℃ ~ 45℃
Size (W x H x D)237mm x 246mm x 56mmExcellent
322mm x 186mm x  68mm
Weight1.2 kgExcellent
2.3 kg
Certificate
EMC, KC, FCC, CEequivalentEMC, KCC, FCC 
Generate Report

Web reporting or its own program

(Internet Connection X)

Excellent
Web reporting


Certifications